Room silencing, vibration reduction, vibration and noise measurements
Type | Sensitivity | Weight | Temp. Min/Max |
Miniature IEPE Accelerometers | |||
A/128/V Data Sheet |
1 mV/g up to 10 mV/g | 0,19 g | -50°C/+200°C |
A/127/V Data Sheet |
1 mV/g up to 100 mV/g | 1,5 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
A/124/E Data Sheet |
1 mV/g up to 200 mV/g | 2 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
General Purpose IEPE Accelerometers | |||
A/123/E Data Sheet |
1 mV/g up to 250 mV/g | 3,6 - 5,2 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
A/122/V Data Sheet |
10 mV/g up to 1 V/g | 12 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
A/120/V Data Sheet |
10 mV/g up to 1 V/g | 12,5 - 32,6 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
A/123/B Data Sheet |
1 mV/g up to 250mV/g | 4,8 g | -55°C/+125°C |
A/123/BT Data Sheet |
1 mV/g up to 250mV/g | 4,8 g | -55°C/+125°C |
High Sensitivity IEPE Accelerometers | |||
A/121/V Data Sheet |
100 mV/g up to 3 V/g | 90 g | -50°C/+125°C (Standard) -50°C/+185°C (HT) |
Seismic Micro G IEPE Accelerometers | |||
A/1600 Data Sheet |
1 V/g up to 5 V/g | 114,5 g | -50°C/+125°C |
A/1800 Data Sheet |
10 V/g | 400-429 g | -50°C/+125°C |
Calibration reference IEPE Accelerometers | |||
A/120/CR Data Sheet |
10 mV/g or 100 mV/g | 24 g | -50°C/+125°C |
High Shock IEPE Accelerometers | |||
A/161/V Data Sheet |
0,5 mV/g | 10 g | -40°C/+121°C |
A/162/V Data Sheet |
0,2 mV/g | 10 g | -40°C/+121°C |
A/163/V Data Sheet |
0,1 mV/g | 16 g | -40°C/+121°C |
Industrial IEPE Accelerometers | |||
A/1107/V Data Sheet |
1 mV/g up to 250 mV/g | 85 g | +185°C |
A/172/VF Data Sheet |
100 mV/g | 130 g | +185°C |
Low Cost Industrial IEPE Accelerometers | |||
A/140 Data Sheet |
100 mV/g | 85 g | -50°C/+120°C |
A/140/SC Data Sheet |
100 mV/g | 149 g | -50°C/+120°C |
A/140/C Data Sheet |
100 mV/g | 99 g | -50°C/+120°C |